Bussmann LPN-RK-10SP

Bussmann Low-Peak™ LPN-RK-10SP Current Limiting Time Delay Fuse, 10 A, 250 VAC/125 VDC, 300/100 kAIC Interrupt, RK1 Class, Cartridge Body

  • Manufacturer Name: Eaton
  • MPN: LPN-RK-10SP
  • Brand Name: Bussmann
  • UPC: 051712538305
  • FEPN: LPN-RK-10SP BU
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading loading

Bussmann's UL Class RK1 fuse offering includes the industry's most recognized Low-Peak dual-element, current-limiting, time-delay fuses (LPN-RK and LPS-RK) which are also available with optional indication on select ratings (see product data sheet). Complementing the Low-Peak product offering is Bussmann's Limitron family of fast-acting fuses (KTN-R, KTS-R, KWN-R and KWS-R) fuses.

Bussmann Low-Peak™ Fuse, Current Limiting Time Delay, Series: LPN-RK, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 10 A, 250 VAC/125 VDC, 300/100 kAIC Interrupt, Class: RK1, 8 s at 500% Response, Ferrule End Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.56 in Dia x 2 in L Body Size

Body Size       :      0.56 in Dia x 2 in L
Element       :      Dual
Indicating/Non-Indicating       :      Non-Indicating
Material       :      Melamine
Mounting Type       :      Holder
Rejection/Non-Rejection       :      Rejection
Response Time       :      8 s at 500%
Series       :      LPN-RK
Terminal Type       :      Ferrule End
Type       :      Current Limiting Time Delay
Amperage Rating       :      10 A
Voltage Rating       :      250 VAC/125 VDC
Interrupt Rating       :      300/100 kAIC
Class       :      RK1
Body Type       :      Cartridge
  • Fast short circuit protection and dual element, time delay performance provide ultimate protection
  • Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
  • Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
  • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak™ fuses
  • Consistent 2:1 ampacity ratios for all Low-Peak™ fuses make selective co-ordination easy
  • Time delay permits 130% FLA sizing for back-up motor protection
  • Inventory consolidation of class RK1/RK5/H fuses for reduced SKU investment and minimizing potential for misapplying fuse
  • Separate overload and short circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current-limitation and selective co-ordination ratio of 2:1 (within Low-Peak™ fuse family) helps prevent widespread blackouts
  • Protects against 1 ph motor damage
  • Proper sizing can provide "no damage" type 2 co-ordinated protection for NEMA and IEC motor controllers
  • Electrically isolated end caps for additional safety
  • pdfLine Drawing https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_44e36d32fc41d56126896e8776e5962babd75bae4b083c7a4f8fc9d1659fefd6.pdf
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_732af43942f3b83bff965337812811f75f4fbe4cea1c1e2c389ad0fbbd748eec.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_8c7c005853100e76b4df43ed7a521432703f91fe4445c70c9bbc7d124850d55a.pdf
  • videoVIDEO LINK https://www.youtube.com/watch?v=YMvqUyoETXk