Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500% of rated current (8 seconds for 1/10-30A sizes).
Bussmann Fusetron™ Renewable Fuse, Current Limiting Time Delay, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 40 A, 600 VAC/250 VDC, 200/20 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Ferrule End Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Fiberglass, 1.06 in Dia x 5.5 in L Body Size
| Body Size |
: |
1.06 in Dia x 5.5 in L |
| Element |
: |
Dual |
| Indicating/Non-Indicating |
: |
Non-Indicating |
| Material |
: |
Fiberglass |
| Mounting Type |
: |
Holder |
| Rejection/Non-Rejection |
: |
Rejection |
| Response Time |
: |
10 s at 500% |
| Series |
: |
FRS-R |
| Terminal Type |
: |
Ferrule End |
| Type |
: |
Current Limiting Time Delay |
| Amperage Rating |
: |
40 A |
| Voltage Rating |
: |
600 VAC/250 VDC |
| Interrupt Rating |
: |
200/20 kAIC |
| Class |
: |
RK5 |
| Body Type |
: |
Cylindrical |
- Dual element feature provides the best time delay performance, allowing closer sizing and superior protection of motors and transformers
- Closer sizing allows for smaller fuses and less costly switches
- Class RK5 fuses with a 200 kA interrupt rating for use in a broad range of applications
- Provides motor overload, ground fault and short circuit protection
- Helps protect motors against burnout from overloads and 1 ph when sized properly
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- Offers a 10 s time delay at 5 times the rated current
- The time delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses
- Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
- Provides current limitation to help protect downstream components from high fault currents
- Gives motor running back-up protection to motors without extra costs
-
Line Drawing
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_21157e528f717a58f6f6e091e89b84dc885f6c75dc547cf4377d3547d64ac3e2.pdf
-
Specification Sheet
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_a45e551437d17f331080617d8dbe6ef0229835c364a3e2e39d94116f9c7d978b.pdf
-
Catalog
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_c85790299cf54e7461bd1f247fc23e8817bf201e0cbc9266bf262bd79c0a3cd8.pdf
-
VIDEO LINK
https://www.youtube.com/watch?v=YMvqUyoETXk